Radici Radiflam A FR 100 NT PA66

Technical Data Sheet: Radici Radiflam A FR 100 NT PA66

This document provides a comprehensive overview of Radici Radiflam A FR 100 NT, a flame-retardant Polyamide 66 (PA66) grade developed by RadiciGroup High Performance Polymers. The data presented is sourced from reliable technical databases, ensuring accuracy and consistency for engineering and design applications. The material is designed for injection molding and profile extrusion, offering excellent fire retardancy without halogens or phosphorus, making it suitable for safety-critical components.

1. General Information

  • Material Type: Polyamide 66 (PA66)
  • Grade: Radiflam A FR 100 NT
  • Description:

    Radiflam A FR 100 NT is a flame-retardant injection molding grade of PA66, free of halogens and phosphorus. Supplied in natural color, it is ideal for parts requiring high fire retardancy, particularly thin-walled components or those with long flow paths. It achieves a V-0 rating at 0.4 mm thickness per UL-94 standards, ensuring compliance with stringent fire safety requirements. The material is heat-stabilized, enhancing its performance in demanding environments.

2. Processing Information

  • Processing Methods:
    • Injection Molding
    • Profile Extrusion
  • Delivery Form: Granules, Natural Color
  • Additives: Release agent
  • Special Characteristics:
    • Flame retardant
    • Halogen-free
    • Phosphorus-free
    • Heat stabilized

3. Processing Recommendations

To achieve optimal part quality and performance, adhere to the following processing guidelines:

  • Pre-drying:
    • Temperature: 80 °C
    • Time: 2-4 hours
    • Maximum Humidity: ≤0.1 %
  • Melt Temperature: 270-290 °C
  • Mold Temperature: 60-80 °C
  • Injection Speed: Medium
  • Extrusion Temperature: 270-290 °C

The material is delivered in moisture-proof packaging, ready for processing. Pre-drying is critical to maintain a maximum water content of 0.10% for best results.

Key Properties

4. Mechanical Properties

The mechanical properties are tested in both dry and conditioned states, as per standard testing protocols. The table below summarizes key mechanical characteristics:

Property Dry Conditioned Test Standard
Tensile Modulus (MPa)35002600ISO 527
Charpy Impact Strength, +23°C (kJ/m²)75120ISO 179/1eU
Charpy Notched Impact Strength, +23°C (kJ/m²)4.56.5ISO 179/1eA
Charpy Notched Impact Strength, -30°C (kJ/m²)4Not specifiedISO 179/1eA

These properties indicate good strength and toughness, with improved impact resistance in the conditioned state, making it suitable for robust applications.

5. Thermal Properties

Thermal properties are critical for applications involving heat exposure or fire safety. The following table details the thermal performance:

Property Dry Conditioned Test Standard
Melting Temperature, 10°C/min (°C)260Not specifiedISO 11357-1/-3
Deflection Temp., 1.80 MPa (°C)70Not specifiedISO 75-1/-2
Deflection Temp., 0.45 MPa (°C)200Not specifiedISO 75-1/-2
Vicat Softening Temperature, B (°C)220Not specifiedISO 306
Burning Behaviour, 1.5 mmV-0 (0.4 mm)Not specifiedIEC 60695-11-10
Yellow Card AvailableYes--

The V-0 rating at 0.4 mm thickness highlights its exceptional fire resistance, ideal for safety-critical components.

6. Electrical Properties

Electrical properties are essential for applications requiring insulation. The table below summarizes key electrical characteristics:

Property Dry Conditioned Test Standard
Volume Resistivity (Ohm*m)1E131E11IEC 62631-3-1
Surface Resistivity (Ohm)Not specified1E10IEC 62631-3-2
Electric Strength (kV/mm)3126IEC 60243-1
Comparative Tracking Index600Not specifiedIEC 60112

These properties demonstrate good electrical insulation, particularly in dry conditions, suitable for electrical housings and connectors.

7. Other Properties

Additional properties influencing material selection include:

Property Value (Dry) Test Standard
Water Absorption (%)7.7Sim. to ISO 62
Humidity Absorption (%)1.8Sim. to ISO 62
Density (kg/m³)1170ISO 1183

8. Molding Shrinkage

  • Parallel/Normal: 1.1 %
  • Test Standard: ISO 294-4, 2577

This low shrinkage ensures dimensional stability in molded parts.

9. Oxygen Index

  • Oxygen Index: 35 %
  • Test Standard: ISO 4589-1/-2

The high oxygen index further confirms the material’s excellent flame-retardant properties.

10. Applications

Radiflam A FR 100 NT is ideal for:

  • Electrical and electronic components (e.g., connectors, housings)
  • Automotive parts requiring fire safety
  • Thin-walled components or parts with complex geometries
  • Applications needing compliance with UL-94 V-0 standards

11. Additional Information

  • For further details, including application examples and technical articles, visit Material Data Center.
  • Note: Some properties, such as Charpy notched impact strength at -30°C and surface resistivity in dry conditions, are not specified for conditioned states. Consult RadiciGroup for specific application requirements.

12. Data Accuracy and Sources

  • The data is sourced from the Material Data Center, a trusted database for material properties.
  • Cross-verification with summaries from UL Prospector confirms the material’s description and key characteristics.
  • All properties are reported per specified test standards to ensure reliability and consistency.

This technical data sheet provides a complete and accurate overview of Radici Radiflam A FR 100 NT PA66, covering its properties, processing guidelines, and applications. It is designed to assist engineers, designers, and manufacturers in selecting and utilizing this material effectively.

finding the right polymer supplier?

We’re here to help. Don’t hesitate to reach out—we’re ready to support you in building your dreams. Start today and create a better tomorrow.

get in touch